Product Details:

Place of Origin: Zhejiang,China(Mainland)
Brand Name: YONGDE
Certification: ISO9001, veiki
Model Number: GW4

Payment & Shipping Terms:

Minimum Order Quantity: 1pcs
Price: negotiation
Packaging Details: wooden case
Delivery Time: 21days per container
Payment Terms: T/T or western Union or L/C or PayPal, MoneyGram, D/P, D/A
Supply Ability: 1,000 pcs per month
Contact Now
Detailed Product Description
Max. Voltage: 126KV Type: GW4
Standard: IEC 62271-102: 2005 IEEE Std C37.30-1997 Apply To: Power Distribution Equipment
Max. Current: 650A Application: AC System
Installation: Easy Quality: High

Mounted Outdoor Switch Disconnector Pole mounted Isolating Switch Of High Voltage

 

 

Description of GW4 Disconnect Switch:

 

This type disconnector is a kind of HV outdoor electric equipments used in three-phase AC 50Hz electrical system . It is used for swithing-on/off the HV circuit when there is no load in the circuit in order to charge or transfer the circuit and also dissconnect the current with the bus bar , breaker or any other HV electrical equipments when overhauling the circuitry .

 

GW4 Series Parameters:

 

No Items Technical parameter
1 Rated Voltage kV 40.5 12 18 20
2 Nominal system voltage kV 35 10 15 20
3 Rated current A 630;1250;1600;2000;2500;3150;4000
4 Rated Short Time withstand current and Time kA/s 25~50/4
5 Rated Peak withstand current kA 63~125
6 1min power frequency withstand voltage (effective value) kV To earth 95/85 42 45 65
To phase 95/85      
Across Isolating DS 118 53 55 79
7 Lightning Impulse wishstand voltage(peak value) KV To earth 185 75 105 125
To phase 185      
Across Isolating DS 210 85 120 145
8 Rated mechanical terminal load N Level of lateral load 500 500 500 500
Level of vertical load 250 250 250 250
Vertical 500 500 500 500
9 The min distance of insulation against ground mm 400
10 Max Man Operative Moment N. m 200
11 Motor Drive operating mechanism control voltage V AC220,380; DC110,220
12 Motor Drive operating mechanism motor voltage V AC220,380; DC110,220

 

Disconnectors' Drawing:

GW4 Type Outdoor Switch Disconnector , Pole Mounted Isolating Switch For AC System

Installation way:

The disconnectors and earthing switches are pre-assembled and ad­justed in our works as complete as possible. The construction is designed so that all disconnectors can be instal­led and adjusted at site very easily, without the need of any special tools. Hapam provides clear installation instructions and assembly drawings.