Home ProductsHigh Voltage Disconnect Switch

252KV HV Electrical Disconnect Switch With Earth Disconnector

Good quality Lightning Surge Arrester for sales
Good quality Lightning Surge Arrester for sales

——

I'm Online Chat Now

252KV HV Electrical Disconnect Switch With Earth Disconnector

China 252KV HV Electrical Disconnect Switch With Earth Disconnector supplier

Large Image :  252KV HV Electrical Disconnect Switch With Earth Disconnector

Product Details:

Place of Origin: Zhejiang,China(Mainland)
Brand Name: YONGDE
Certification: ISO9001
Model Number: GW38-252

Payment & Shipping Terms:

Minimum Order Quantity: 1pcs
Price: negotiation
Packaging Details: wooden case
Delivery Time: 21days per container
Payment Terms: T/T or western Union or L/C or PayPal, MoneyGram, D/P, D/A
Supply Ability: 1,000pcs per month
Contact Now
Detailed Product Description
Sort: Disconnector Switch Max. Voltage: 252KV
Usage: Switching Standard: IEC 62271-102: 2005 IEEE Std C37.30-1997
Price: Best Price Quality: High Quality

High Voltage Outdoor Isolator Disconnector Switch 252KV

 

Main Description:

 

GW38-40.5~252/630~4000 Type Disconnector Switch is good for reducing the distance and station arranging, especially for outdoor station.

 

Because of electric rod's self-rotation and switching structure and having self-locking function, it has strong property of motor performance resistance. Meanwhile, it can resist motor, wind pressure, earthquake and other outside power.

 

Technical Parameter:

 

1. 252kv voltage disconnector

2. We have 20 years exprience

3. Best price & Best quality

 

Parameter Table
No Items Technical parameter
1 Rated Voltage kV   72.5 126 252
2 Nominal system voltage kV   66 110 220
3 Rated current A 630;1250;1600;2000;2500;3150;4000
4 Rated Short Time withstand current and Time kA/s 25~50/4
5 Rated Peak withstand current kA 63~125
6 1min power frequency withstand voltage (effective value) kV To earth 140 230 460
To phase 140 2300 460
Across Isolating DS 180 230+70 460+145
7 Lightning Impulse wishstand voltage(peak value) KV To earth 325 550 1050
To phase 325 500 1050
Across Isolating DS 385 550+100 1050+150
8 Rated mechanical terminal load N Level of lateral load 750 1500 2000
Level of vertical load 500 1000 1500
Vertical 750 1000 1250
9 The min distance of insulation against ground mm   600 1000 2000
10 Max Man Operative Moment N. m 200
11 Motor Drive operating mechanism control voltage V AC220,380; DC110,220
12 Motor Drive operating mechanism motor voltage V AC220,380; DC110,220